American Journal of Epidemiology Advance Access published online on May 4, 2006
American Journal of Epidemiology, doi:10.1093/aje/kwj160
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1 Institute of Medical Epidemiology, Biometry and Informatics, Medical Faculty, University of Halle-Wittenberg, Halle, Germany
* To whom correspondence should be addressed. Many surveys and cohort studies have used a random-zero sphygmomanometer blood pressure device (RZS) to measure subjects' blood pressure and to assess the value of blood pressure in predicting cardiovascular events. Recent studies used automated oscillometric blood pressure devices (AODs) that systematically measure higher blood pressure values than RZSs do, hampering comparability of values between these studies. In 2000-2003, the authors randomly used both an RZS and an AOD in an ongoing cohort study in Germany. This analysis aimed to compare blood pressure values by device and to develop an algorithm to convert estimates of blood pressure values from one device to the other. In a randomized subset of 2,365 subjects aged 45-75 years, each subject was measured three times with each device in a randomized order. The mean difference (AOD-RZS) between the devices was 3.9 mmHg for systolic blood pressure and 2.6 mmHg for diastolic blood pressure. The authors found that linear regression models including age, sex, and blood pressure level can be used to convert RZS blood pressure values to AOD blood pressure values, and vice versa. Results may help to better compare blood pressure values in epidemiologic studies that used different blood pressure devices.
Received October 7, 2005
Accepted January 19, 2006
PRACTICE OF EPIDEMIOLOGY
Algorithms for Converting Random-Zero to Automated Oscillometric Blood Pressure Values, and Vice Versa
Andreas Stang 1 *,
Susanne Moebus 2,
Stefan Möhlenkamp 3,
Nico Dragano 4,
Axel Schmermund 5,
Eva-Maria Beck 2,
Johannes Siegrist 4,
Raimund Erbel 3,
Karl-Heinz Jöckel 2,
and
on behalf of the Heinz Nixdorf Recall Study Investigative Group
2 Institute of Medical Informatics, Biometry and Epidemiology, University Hospital, University of Duisburg-Essen, Essen, Germany
3 West German Heart Center, University Hospital, University of Duisburg-Essen, Essen, Germany
4 Institute of Medical Sociology, University of Duesseldorf, Duesseldorf, Germany
5 Cardioangiologisches Centrum, Bethanien, Frankfurt, Germany
Andreas Stang, E-mail: andreas.stang{at}medizin.uni-halle.de
![]()
Abstract ![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
M. Kivimaki, G. D. Batty, A. Singh-Manoux, J. E. Ferrie, A. G. Tabak, M. Jokela, M. G. Marmot, G. D. Smith, and M. J. Shipley Validating the Framingham Hypertension Risk Score: Results From the Whitehall II Study Hypertension, September 1, 2009; 54(3): 496 - 501. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Erbel, J. A.C. Delaney, N. Lehmann, R. L. McClelland, S. Mohlenkamp, R. A. Kronmal, A. Schmermund, S. Moebus, N. Dragano, A. Stang, et al. Signs of subclinical coronary atherosclerosis in relation to risk factor distribution in the Multi-Ethnic Study of Atherosclerosis (MESA) and the Heinz Nixdorf Recall Study (HNR) Eur. Heart J., November 2, 2008; 29(22): 2782 - 2791. [Abstract] [Full Text] [PDF] |
||||
![]() |
RE: "ALGORITHMS FOR CONVERTING RANDOM-ZERO TO AUTOMATED OSCILLOMETRIC BLOOD PRESSURE VALUES, AND VICE VERSA" Am. J. Epidemiol., April 1, 2007; 165(7): 848 - 848. [Full Text] [PDF] |
||||